Poly-Spectrum-8-V-SM for Small and Medium-sized Animals

Please click the button below to request a quote for this product.

  • Highlights
  • Features
  • Specifications
  • Standard Set
  • Warranty
  • Downloads
  • References

Electrocardiography (ECG) is a widely used investigative tool within veterinary cardiology and is important in the general assessment of patients to detect rhythm and conduction disturbances, which can offer clues to possible coronary problems and left ventricular hypertrophy.

 

Poly-Spectrum-8-V-SM Veterinary Digital ECG System is a portable instrument ideal for the veterinary clinic, clinical networks, and experimental research in small animals.

 

Poly-Spectrum-8-V-SM key features:

 

· Standard 12-lead ECG.

 

· Skin-safe electrodes.

 

· Clear artefact-free recording and processing.

 

· Intelligent software with veterinary-specific algorithm, numeric ECG data.

 

· Intra-operative ECG monitoring during surgery and recovery, and experimental research.

 

· Extensive database, HL7 compatibility.

 

· Data export to Excel and statistical software for further analysis.

Standard 12-lead ECG

 

Poly-Spectrum-8-V-SM can record ECG from standard limb leads (I, II, III), augmented limb leads (aVL, aVR, aVF) and precordial leads (V1...V6) (available upon request).  The recorded ECG data are displayed on the screen, stored in the computer database, shared, and printed out on any printer.

 

Skin-safe electrodes

 

Unlike the most commonly used needle electrodes, Poly-Spectrum-8-V-SM Alligator Clip Electrodes are skin-safe, thereby preventing animal skin injury and the risk of infection.  At the same time, the electrodes enable better skin contact, lower impedance, and high-quality ECG recording.

 

Intelligent software with Veterinary-specific algorithm

 

The supplied software features a veterinary-specific algorithm.  It ensures automatic QRS complex detection, calculation of all temporal parameters, and report generation.  

The QRS complex is the combination of three of the graphical deflections seen on a typical electrocardiogram (EKG or ECG).  It is usually the central and most visually prominent part of the ECG tracing.  It corresponds to the depolarization of the right and left ventricles of the heart and contraction of the large ventricular muscles.

 

Exceptionally high-quality low-noise physiological preamplifiers, combined with high-efficiency digital filters and signal-processing algorithms, were specifically designed for Poly-Spectrum-8-V-SM based on extensive research and development.  They ensure excellent noise suppression, clear ECG recording, and reliable, reproducible calculation of ECG parameters.

 

This allows not only better diagnostics, but also reliable monitoring for any changes in follow-up assessments over prolonged periods of time.

 

Intra-operative ECG monitoring

 

Designed to work in the electro-magnetically harsh OR environment, Poly-Spectrum-8-V-SM can be used as a reliable ECG monitor during surgery.  It ensures sound notification for every detected QRS complex and shows the current heart beat rate in real time.

 

Database and data export

 

ECG measurement data and interpretation, as well as exam reports, are saved in a well-organized software database.  The data and reports can be printed out either at the time of the assessment, or at a later time, and shared with a referring doctor or researcher.

 

ECG parameters can be exported to Excel spreadsheets and other statistical software for further data analysis making it an ideal tool for research projects.

 

Portability

 

The device is pocket-sized, and can be placed in a Carrying Case – along with a notebook computer – and can be powered from the computer.  Hence, it can be used both in the clinic and on an outpatient visit.

 

This means that long-term ECG monitoring system is always at hand no matter where you perform surgery: at your clinic or at a patient’s location.

 

Software compatibility

 

Neurosoft Software enables highly efficient operation – saving both capital and operating costs – through a number of compatibility features:

 

Multiple Neurosoft Software:  Neurosoft Software for various Neurosoft instruments can be installed on the same computer – with no conflict between them.  Moreover, all software can share a single database – for greater convenience and work-flow efficiency.

 

Multiple computers:  Although only one computer can be used for diagnostic test data recording, each Neurosoft Software License allows using software on an unlimited number of computers.  Thus, the data can be recorded on one computer, and then, the data can be shared, analyzed, reviewed on other computers – with no additional Software Licenses.

 

Other applications:  Neurosoft Software can operate on a computer with Microsoft Office applications – Word, Excel, Outlook, PowerPoint, Access, Project, as well as Adobe and accounting software.  This is particularly efficient in smaller clinics.

 

Internet:  Computers with Neurosoft Software installed can be connected to the Internet.  In an unlikely and rare event that a Microsoft Operating System update affects a Neurosoft software component, it can be restored by Neurosoft software re-installation, with no loss of data. 

 

Information system integration

 

Most clinics, networks and research institutions are equipped with information systems to store and process their data.  HL7 (Health Level 7) is the most commonly used interface engine for exchange, integration, sharing and retrieval of electronic data.

 

HL7-compatibility allows integrating POLY-SPECTRUM-8/V into the information system of a veterinary clinic, clinical network, or research institution.

 

Disinfection

 

Electronic Unit – soft cloth gently wrung in phenols (Bacillotex® etc.), or 70% alcohol, or 0.5% chlorohexidine.

 

If dangerous virus contamination is suspected – aldehydes (Cidex® etc.), or chlorinates (Diversol BX® etc.).

 

Interface cables and power cords – soft cloth moistened with disinfectant, for example, 1% chloramine solution or 3% hydrogen peroxide solution.

ECG Channels

Number of channels

8

Input Voltage range

0.03 5 mV

Ratio error of voltage measurement in the amplitude range:

· < 500 µV

· from 500 µV to 5 mV

 

 

 

within 25 µV

within 7%

Input equivalent noise level

20 µV

Bandpass frequency response flatness:

· from 0.5 to 60 Hz

· from 60 to 75 Hz

 

from −10% to +5%

from −30% to +5%

Relative error of interval measurement

within ±7%

Relative error of calibration pulses recording

within ±5%

Heart rate measurement range

30–240 beats per minute

Relative error of heart rate measurement

±1 beats per minute

Control of electrode placement quality

available

Control of electrode falloff during ECG recording

available

Defibrillation protection

available

Common-mode rejection ratio

≥ 100000 ( 100 dB)

Input impedance

≥ 20 MΩ

General Parameters and Characteristics

Electronic Unit Interface with computer

USB

Supply voltage:

· Electronic Unit

· Desktop PC-based system

· Notebook PC-based system

 

5 V DC (from USB)

 

110 V AC (60 Hz) / internal battery

Dimensions:

 

· Electronic unit

(126 x 68x 25) ± 5 mm

· Carrying Case

(240 x 185 x 130) ± 10 mm

Cable length:

· PC connection cable

· ECG cable (for limb leads)

· ECG cable (for chest leads)

· ECG cable NS017103.008

 

2.5 ± 0.2 м

2.0 ± 0.1 м

1.5 ± 0.1 м

1.45 ± 0.1 м

Weight:

· Electronic Unit

· Carrying Case

· Packed System (without computer)

 

0.3 ± 0.05 kg

0.15 ± 0.05 kg

1.5 kg

Applied parts

CF type with protection against defibrillator discharge

Transportation Conditions

Temperature

from -25 to +60°C

Humidity

20 – 95% (non-condensing)

Atmospheric pressure

from 70 kPa

Storage Conditions

Temperature

from +5 to +40°C

Humidity

30-85% (non-condensing)

Atmospheric pressure

70-106 kPa

Operation Conditions

Temperature

from +10 to +35°C

Humidity

30-85% (non-condensing)

Atmospheric pressure

70-106 kPa

Electrical Safety and Electromagnetic Compatibility

 

Electromagnetic compatibility (EMC) is provided by conformance to IEC 60601-1-2-2014 (EN 60601-1-2:2015) requirements.

 

The system is intended for operation in electromagnetic environment, which special features are specified in Annex 2.

 

Portable and mobile RF communication equipment can affect the system operation.

 

As for electrical safety, the system satisfies IEC 60601-1:2012 (AAMI/ANSI ES 60601-1:2005/(R2012) and A1:2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013) and IEC 60601- 1-2-2014 (EN 60601-1-2:2015) and IEC 60601-2-25:2011 (EN 60601-2-25:2015).

 

Electronic Unit is supplied with DC power by regulated power supply through USB interface, it has double isolation and CF-type applied parts with protection against defibrillator discharge according to IEC 60601-1:2012 (AAMI/ANSI ES 60601- 1:2005/(R2012) and A1:2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013).

Poly-Spectrum-8/V Electronic Unit

1 pcs.

4-lead ECG Cable with Banana Connector 2.0 m

1 pcs.

Veterinary ECG Electrode - alligator clip

8 pcs.

Electrode Gel Unimax , 250 g

1 pcs.

User Manual "Poly-Spectrum.NET"

1 pcs.

Carrying Case

1 pcs.

License for the use of software Poly-Spectrum.NET" with additional software module "Poly-Spectrum.NET/Veterinary

1 pcs.

 

NOTE:  Computer (PC) is not included in Standard Set, but can be supplied as per Customer requirements.

 

Minimum requirements to PC:

 

· For the software based on Microsoft .NET platform dual core processor with ≥ 2.6 GHz clock rate and random-access memory (RAM) of ≥ 2 GB is required (4 GB is recommended).  For other software, the clock rate is desired to be ≥ 1200 MHz and RAM ≥ 512 MB.

 

· Either Windows 8 or Windows 10 operating system is required.  Both 32-bit and 64-bit editions are supported.

 

· A ground wire must be available as the third wire of the power outlet.  It is not allowed to connect the computers using adaptors that insulate the third wire.

 

Customized accessory sets

 

Accessory set, such as electrodes types and quantities, can be customized to specific needs of a clinic or research lab.

 

Contact us to discuss your accessory needs.

Electronic Unit limited warranty term – 2 years.

 

During the warranty term, repair is free, and if repair is impossible, Electronic Unit is replaced.  Warranty does not cover mechanical damage and unauthorized opening of Electronic Unit, and defects caused by misuse, and any product that has been altered or modified in any way.

 

Warranty repair is professionally performed at the Neurosoft Service Center in Ivanovo, RF.  Transportation costs to the Service Center are covered by the Customer, return transportation is covered by Neurosoft.

 

Customer pays return shipping charges.  We are responsible for the return shipping charges of replaced / repaired products.  Products found to be non-defective will be returned at customer's expense.

 

Extended warranty is available. Contact us for details.

 

Accessories (cables, bands, etc.) – 30 days.

 

Single-use items (electrodes, gels, pastes, etc.) are not covered.

 

Software updates are free of charge.  Please fill out the online Form to receive a download link to the version you are requesting.

Request a Quote for
Poly-Spectrum-8-V-SM for Small and Medium-sized Animals

To contact us, please complete the form below and click on "Request Quote".

Required fields are marked with a *

  •  Please check if you would like your name added to our mailing list.

Please Click I’m not a robot box and click the “Request Quote” button below to submit your message.